NTP 101 —  Replace a B-0404-A
NTP 101-2 November 2013 Alcatel-Lucent 7302 ISAM | 7330 ISAM FTTN | 7360 ISAM FX ONT R04.06.02
Edition 01 3FE 55873 AAAA TCZZA
ONT Product Information Guide
Safety information
Read the following safety information before replacing the unit. 
Procedure
Use this procedure to replace a B-0404-A business ONT. 
1 Deactivate the ONT services (DLP 131).
If you are using SLID, this step is not required. The ONT and the services can 
remain in service (IS).
2 Disconnect the Ethernet, E1/T1, UPS, and power cables from the ONT (DLP 132). 
Figure NTP 101-1 shows the connections.
Danger 1 —  Contact the local utility company before you connect the 
B-0404-A to the utilities.
Danger 2 —  Observe the local and national laws and regulations that 
may be applicable to this installation.
Warning —  This equipment is ESD sensitive. Proper ESD protections 
should be used when connecting or removing the fiber optic cable.
Caution —  Keep out of direct sunlight. Prolonged exposure to direct 
sunlight can damage the B-0404-A.
Note —  Observe the following:
• The B-0404-A should be installed in accordance with the applicable 
requirements of the NEC or CEC. Local authorities and practices take 
precedent when there is conflict between the local standard and the 
NEC or CEC. 
• The B-0404-A must be installed by qualified service personnel.
• Ensure temperature falls within tolerances as show in section 8.6.