NTP 104 —  Replace a B-0404G-B business ONT
NTP 104-2 November 2013 Alcatel-Lucent 7302 ISAM | 7330 ISAM FTTN | 7360 ISAM FX ONT R04.06.02
Edition 01 3FE 55873 AAAA TCZZA
ONT Product Information Guide
Safety information
Read the following safety information before replacing the unit. 
Procedure
Use this procedure to replace a B-0404G-B business ONT. 
1 Deactivate the ONT services (DLP 131).
If you are using the SLID feature, this step is not required. The ONT and the 
services can remain in service (IS).
2 If the B-0404G-B is mounted in an outdoor enclosure, open the access cover on the 
outdoor enclosure by loosening the pin-in-hex screw.
3 Disconnect the ground wire, Ethernet, DS1, UPS, and power cables from the ONT 
(DLP 132). For the location of the ports on the ONT; see Figure NTP 104-1.
Danger 1 —  Contact the local utility company before you connect the 
enclosure to the utilities.
Danger 2 —  Observe the local and national laws and regulations that 
may be applicable to this installation.
Warning 1 —  This equipment is ESD sensitive. Proper ESD protections 
should be used when removing the fiber access cover of the business 
ONT.
Warning 2 —  The intrabuilding port(s) of the equipment or 
subassembly is suitable for connection to intrabuilding or unexposed 
wiring or cabling only. The intrabuilding port(s) of the equipment or 
subassembly MUST NOT be metallically connected to interfaces that 
connect to the OSP or its wiring. These interfaces are designed for use 
as intrabuilding interfaces only (Type 2 or Type 4 ports as described in 
GR-1089-CORE, Issue 5) and require isolation from the exposed OSP 
cabling. The addition of Primary Protectors is not sufficient protection 
in order to connect these interfaces metallically to OSP wiring.
Caution —  Keep ONTs out of direct sunlight. Prolonged exposure to 
direct sunlight can damage the unit.
Note —  Observe the following:
• The ONT should be installed in accordance with the applicable 
requirements of the NEC or CEC. Local authorities and practices take 
precedent when there is conflict between the local standard and the 
NEC or CEC. 
• The ONT must be installed by qualified service personnel.
• See the “B-0404G-B unit data sheet” for the temperature ranges for 
ONTs.