NTP 122 — Replace an I-010G-B, I-020G-M, or I-040G-B indoor ONT
NTP 122-2 November 2013 Alcatel-Lucent 7302 ISAM | 7330 ISAM FTTN | 7360 ISAM FX ONT R04.06.02
Edition 01 3FE 55873 AAAA TCZZA
ONT Product Information Guide
Safety information
Read the following safety information before replacing the unit.
Procedure
Use this procedure to replace an I-010G-B, I-020G-M, or I-040G-B indoor ONT.
1 Deactivate the ONT services (DLP 131).
If you are using the SLID feature, this step is not required. The ONT and the
services can remain in service (IS).
2 Power down the ONT unit by using the ON/OFF power switch.
3 Disconnect the Ethernet, fiber optic, and power cables from the ONT (DLP 132).
For the location of the ports on the ONT; see Figure NTP 122-1.
Danger — Observe the local and national laws and regulations that
may be applicable to this installation.
Warning — This equipment is ESD sensitive. Proper ESD protections
should be used when removing the fiber access cover of the indoor ONT.
Caution — Keep indoor ONTs out of direct sunlight. Prolonged
exposure to direct sunlight can damage the unit.
Note — Observe the following:
The indoor ONT should be installed in accordance with the
applicable requirements of the NEC or CEC. Local authorities and
practices take precedent when there is conflict between the local
standard and the NEC or CEC.
The indoor ONT must be installed by qualified service personnel.
Indoor ONTs must be installed with cables that are suitably rated
and listed for indoor use.
See I-010G-B, I-020G-M, and I-040G-B detailed specificationsin the
unit data sheet for the temperature ranges for ONTs.