NTP 137 —  Replace an I-011G-A, I-011G-B, I-110G-A, or I-111G-A indoor ONT
NTP 137-4 November 2013 Alcatel-Lucent 7302 ISAM | 7330 ISAM FTTN | 7360 ISAM FX ONT R04.06.02
Edition 01 3FE 55873 AAAA TCZZA
ONT Product Information Guide
8 If required, have approved service personnel who are trained to work with optic 
fiber clean the fiber optic connection. See DLP 134 for more information about 
fiber optic handling, inspection, and cleaning.
9 Connect the SC/APC adaptor to the fiber optic port (DLP 125).
10 Connect the power supply according to manufacturer specifications.
11 Connect the power cable with an 8-pin Molex connector to the ONT unit.
12 Power up the ONT unit by using the ON/OFF power switch.
13 If necessary, reset the ONT (DLP 126). 
14 If used, configure the SLID (DLP 129).
15 Verify the ONT LEDs and voltage status (DLP 127).
16 Activate and test the services (DLP 128).
17 STOP. This procedure is complete.
Danger —  Fiber optic cables transmit invisible laser light. To avoid eye 
damage or blindness, never look directly into fibers, connectors, or 
adapters.
Warning —  Be careful to maintain a bend radius of no less than 1.5 
inches (3.8 cm) when connecting the fiber optic cable. Too small of a 
bend radius in the cable can result in damage to the optic fiber.
Note —  Observe the following:
• Units must be powered by a Listed or CE approved and marked 
limited power source power supply with a minimum output rate of 
12 V dc, 1.25 A.
Note —  A new SLID or the old SLID may be used with the replacement 
ONT. If a new SLID is used, the new SLID must also be programmed at 
the P-OLT using TL1 or a network manager. If the old SLID is used, no 
changes need to be made at the P-OLT; see the Operations and 
Maintenance documentation for the I-011G-A, I-011G-B, I-110G-A or 
I-011G-A for more details.