21 —  I-011G-P unit data sheet
Alcatel-Lucent 7302 ISAM | 7330 ISAM FTTN | 7360 ISAM FX ONT R04.06.02 November 2013 21-11
3FE 55873 AAAA TCZZA Edition 01
ONT Product Information Guide
When using CVLAN translation, or when the same queue is used for multiple pbits, the highest pbit 
value in the queue in the downstream direction will be selected to stomp the pbit in the packet
Simultaneous configuration of a CVLAN port and an S-Tunnel on the same UNI will only be supported 
if these services are provisioned with non-overlapping pbits
The same VLAN port must be used when employing both protocol-based VLAN for PPPoE and 
IPoE-based VLANs
When the VLAN is translated, the pbit value must be modified and the highest pbit value is mapped 
to that GEM port
When more than one Ethernet port is in VLAN translation mode, or set to flexible mode with IGMP 
channels created, the USERSIDE VLAN IDs of those services are different. All downstream multicast 
packets will be tagged on the UNI port with VLAN ID of 4094
Maximum use of multicast on 1 Ethernet port at a time
For C forwarder and S+C CC forwarder, if the VLAN port uses regenerated profiles or regenerated 
pbits, then the downstream traffic can only flow with the derived pbits
When either tip or ring is grounded, DGNONTPOTS tip to ground and ring to ground restrictive 
measurements are simultaneously reported as 0 ohms
100M half is not supported
Considerations and limitations
(2 of 2)