NTP 149 — Replace an I-040G-R indoor ONT
NTP 149-4 November 2013 Alcatel-Lucent 7302 ISAM | 7330 ISAM FTTN | 7360 ISAM FX ONT R04.06.02
Edition 01 3FE 55873 AAAA TCZZA
ONT Product Information Guide
7 Install the power supply according to manufacturer specifications.
8 Connect the power cable to the ONT unit power connector as shown in
Figure NTP 149-1.
9 If necessary, reset the ONT (DLP 126).
10 If used, configure the SLID (DLP 129).
11 Verify the ONT LEDs, voltage status, and optical signal levels (DLP 127).
12 Activate and test the services (DLP 128).
13 STOP. This procedure is complete.
Note — Observe the following:
Units must be powered by a Listed or CE approved and marked
limited power source power supply with a minimum output rate of
12 V dc, 1.25 A.
Note — A new SLID or the old SLID may be used with the replacement
ONT. If a new SLID is used, the new SLID must also be programmed at
the P-OLT using TL1 or a network manager. If the old SLID is used, no
changes need to be made at the P-OLT; see the operations and
maintenance documentation for the OLT for more details.