Focus 61 User Guide Programming Focus 61
67 (118) 9839 0211 01 Edition 2.0
6.5.1 Configuring identifiers
Start Jobs section allows to set the signal that starts a Job.
Set the following parameters:
Input source : source from which the identifier will come from:
o Barcode barcode reader
o AOP_SETVIN Open Protocol via set VIN message (MID 0050)
o AOP_SETIDENTIFIER Open Protocol via set Identifier message (MID 0150)
Once configured, will be not necessary to tick the box AOP Message>Set Station
IDN to display the string sent to Focus 61 by AOP.
NOTE: If AOP_SETVIN or AOP_SETIDENTIFIER are selected for Job, the AOP
Message > Set Station IDN check box becomes available.
If in Result sources of the Result section, Result source STATION_IDN is selected, the
string sent to Focus 61 by AOP is displayed in the result table.
To create an AOP_SETVIN event with SET_STATION_IDN action without
STARTJOB action, select in Significant String Set Strings Set Station IDN.