Focus 61 User Guide User interfaces
21 (118) 9839 0211 01 Edition 2.0
info
system
overview
General parameters of the controller
packet
Installed release
mainboard
Firmware, LAN, hardware versions of the main board
extension1
Firmware, LAN, hardware versions of the MPC board
script A
Script main boad
script B
Script MPC board
ToolsNet
ToolsNet parametes, if connected
stations
station 1
General information about station 1
station 2
General information about station 1
network
eth A
Parameters of the Ethernet port A
eth B
Parameters of the Ethernet port B
back
Exit the info menu
wrenches
Parameters of the available wrenches
service
Require maintenance
List of wrenches requiring maintenance
Required calibration
List of wrenches with expired calibration
back
Exit the info menu
time
set time
Enter the right date and time
=>
Exit the time menu
back
Exit the main menu
4.3 LEDs
There are three LEDs on the Focus 61 front panel. For each LED,
different functionalities are indicated:
The Blue LED is on when the system is ready.
The Red LED is on when the Focus 61 communicates with
ToolsTalk BLM.
The Green LED blinks when the Focus 61 communicates with
a MWR.
The Yellow LED is on when Focus 61 display shows an error
message.
The yellow LED blinks in the following cases:
- MWR calibration is required: calibration date expired and calibration counter expired.
- Mechanical part replacement in required.
The yellow LED is steady if the System Status is “NOK”. One of the following conditions may have
occurred:
- Wrench needs reset offset in cradle.
- Wrench Overloaded.

Table of Contents