Focus 61 User Guide User interfaces
21 (118) 9839 0211 01 Edition 2.0
General parameters of the controller
Firmware, LAN, hardware versions of the main board
Firmware, LAN, hardware versions of the MPC board
ToolsNet parametes, if connected
General information about station 1
General information about station 1
Parameters of the Ethernet port A
Parameters of the Ethernet port B
Parameters of the available wrenches
List of wrenches requiring maintenance
List of wrenches with expired calibration
Enter the right date and time
4.3 LEDs
There are three LEDs on the Focus 61 front panel. For each LED,
different functionalities are indicated:
• The Blue LED is on when the system is ready.
• The Red LED is on when the Focus 61 communicates with
ToolsTalk BLM.
• The Green LED blinks when the Focus 61 communicates with
a MWR.
• The Yellow LED is on when Focus 61 display shows an error
message.
The yellow LED blinks in the following cases:
- MWR calibration is required: calibration date expired and calibration counter expired.
- Mechanical part replacement in required.
The yellow LED is steady if the System Status is “NOK”. One of the following conditions may have
occurred:
- Wrench needs reset offset in cradle.
- Wrench Overloaded.