6.6.1.1 Configuring Lamp
The Stacklight mounts up to 5 configurable lamps.
If the behaviour of the Stacklight lamp is related to an Event (for example tightening OK), do the
following to configure the behaviour of each lamp of the Stacklight:
1. Starting from Lamp 1, select the Mounted check box: a lamp shows on the Stacklight image on
the left (see the figures below):
NOTE: Configure the lamps of the Stacklight starting from lamp 1 to lamp 5 (in
ascending order). Only the last configured lamp is editable.
For instance, after configuring all the lamps, to edit lamp 3, it is necessary to disable the
last configured lamps in this sequence: lamp 5 lamp 4.
To disable a lamp, remove the check mark in correspondence of the Mounted check box.
2. In the drop-down list box under the Mounted check box, select a condition.
The lamp on the Stacklight is automatically coloured depending on the selected option.
3. Click Setup.
4. In the Setup dialog box, select the Configured check box to associate the event condition to the
lamp.