Focus 61 User Guide Programming Focus 61
79 (118) 9839 0211 01 Edition 2.0
• AOP Relay: set the relay associated to the AOP signal.
If the Multi-Condition option is selected: click the Multi-Condition button ( ). Then in the
I/O Expander sealed – Multi-Condition dialog box, select the Event Condition check box to
use and configure the following parameters: Event timer, Time, Flash, Period and Duty cycle.
Multi-selection for Event Condition is allowed.
5. In the upper-left corner of the New Accessory dialog box, click Save.
6.6.3 Adding a digital output
The digital output is a generic signal generated by the Focus 61 related to an event condition. It is possible
to connect lamps or other devices that mange the output signal of the Focus by using the Digital output
connector.
1. In the Device Files area, right-click I/O Accessories. Then click Add digital output.
2. In the Module area of the New Accessory dialog box, in the S/N drop down list, select the serial
number of the board inside the Controller (internal_1 and internal_2) that manage the output
signal. Each board manages three different output.
3. From the Event Condition drop down list in the Output section, select an event to use as output
signal.
4. If an option different from Multi-Condition is selected, configure the following parameters:
• Event timer: select the event to configure the timer. The available options are: To next
tight and Time.
• Time: set the duration in second of the output signal. It is available if Event timer is set to
Time.
• Flash: select On to enable the flashes of the output.
• Period: set the time in second taken by the signal to complete on-off cycle.
• Duty cycle: set the percentage of one period in which the signal is active.
• AOP Relay: set the relay associated to the AOP signal. If this parameter is set, all the other
parameters are disabled.
If the Multi-Condition option is selected: click the Multi-Condition button ( ). Then in the
Digital output – Multi-Condition dialog box, select the Event Condition check box to use and
configure the following parameters: Event timer, Time, Flash, Period and Duty cycle. Multi-
selection for Event Condition is allowed.
5. In the upper-left corner of the New Accessory dialog box, click Save.