Programming Focus 61 Focus 61 User Guide
9839 0211 01 Edition 2.0 70 (118)
6.5.4 Starting a Job with multiple conditions
Once the Identifiers configuration is completed, the Job can be started by scanning (or sending MID 0050
/ MID 0150 via Open Protocol) all the identifiers, which were previously defined in the configuration.
The identifiers can be scanned or sent in the order defined in the configuration.
6.6 I/O Accessories
In the I/O Accessories section it is possible to configure the accessories connected to the Focus 61:
Stacklight, I/O Expander sealed, Digital output, I/O expander open.
To add a new accessory connected to the Focus 61, do the following:
1. Connect the Stacklight, the I/O Expander Sealed, or I/O Expander Open to the Focus 61.
2. In the Device Files area of the ToolsTalk BLM, right-click I/O Accessories.
3. Select Add Stacklight, Add I/O Expander Sealed, Digital output or Add I/O expander open.
4. In the Device area of the New Accessory dialog box, configure the new accessory to be added.
5. In the upper-left corner of the New Accessory dialog box, click Save.