Focus 61 User Guide Programming Focus 61
59 (118) 9839 0211 01 Edition 2.0
If the operator applies torque over this value, the result is marked as OVSC = Additional torque
limit overload screw exceeded.
Loosening limit
If the operator applies torque in the wrong direction and reach this value, the result is marked as
NEG = False direction of tightening (loosen).
NOTE: If the Loosening limit is set to zero, no results are detected (the function is
disabled).
6.3.3 Pset parameters settings - Angle Limits
Below are the available angle limits:
Minimum angle and Maximum angle
Angle limits to get a positive result (if angle value is considered in the test strategy).
Start final angle
Torque threshold from which the angle measurement starts.
6.3.4 Pset parameters settings - Other settings
Tool size [mm]
Specific length (in millimeters) that characterizes the end fitting tool
installed on the MWR.
NOTE: It is mandatory to enter the proper value. This value is
used to calculate the proper torque applied to the joint.
NOTE: The real Toolsize (length in mm) is only valid for plane
Toolinserts. If the inserted tool is not plane, the Tool size
parameter should be treated as a factor, which is assigned to the
specific tool insert. In this case the physical tool length can differ
from the tool size parameter.
Rehit Value [°]
If the torque reaches the click value within this angle, it means that the screw was already
tightened.
In this case the result is marked as RNOK or ROK, depending on whether the Torque was within
the specified limits.
NOTE: Refer to the paragraph Executing Tightening Operations for further details