Executing tightening operations Focus 61 User Guide
9839 0211 01 Edition 2.0 80 (118)
6.6.4 Adding a I/O Expander open
To add an I/O Expander open to the Focus 61, do the following:
1. In the Device Files area, right-click I/O Accessories. Then click Add I/O Expander open.
2. In the Module area of the New Accessory dialog box, in the S/N drop down list, select the serial
number of the I/O Expander open to configure.
3. From the Event Action drop down list in the Input section, select an event that generate an input
signal on the I/O expander open channel. Then select an Active parameters.
If Multi-Action option is selected: click the Multi-Action button ( ). Then in the I/O
expander open - Multi-Action dialog box, select the Event action check box to use and the
Action Parameters. Multi-selection for the Event Action is allowed.
4. From the Event Condition drop down list in the Output section, select an event that generate an
input signal on the I/O expander open channel. Then, configure the following parameters:
• Event timer: select the event to configure the timer. The available options are: To next
tight and Time.
• Time: set the duration in second of the output signal. It is available if Event timer is set to
Time.
• Flash: select On to enable the flashes of the I/O Expander open LED.
• Period: set the time in second taken by the signal to complete on-off cycle.
• Duty Cycle: set the percentage of one period in which the signal is active.
• AOP Relay: set the relay associated to the AOP signal.
If the Multi-Condition option is selected: click the Multi-Condition button ( ). Then in the
I/O Expander open – Multi-Condition dialog box, select the Event Condition check box to use
and configure the following parameters: Event timer, Time, Flash, Period and Duty cycle.
Multi-selection for Event Condition is allowed.
5. In the upper-left corner of the New Accessory dialog box, click Save.