Focus 61 User Guide Programming Focus 61
73 (118) 9839 0211 01 Edition 2.0
5. On the right of the Setup of Lamp dialog box, set the following parameters:
• Switch: from the Switch drop down list, select the status of the lamp when the event condition
occurs. The available options are: On, Off
• Flash: select the check box to enable the flashing of the lamp and type the time during which
the flash stays on/off. The time is in milliseconds.
• Next tight: select this option to change the lamp status (on or off) at the next tightening.
• Time: type the time to elapse before the lamp changes its status (on or off). The time is in
seconds.
The Behaviour column summarizes the settings of the lamp.
6. Click Set to save the cofiguration.
NOTE: It is possible to set up to 10 event conditions for the same lamp.
After reaching the maximum number of configurable events, a warning message is
displayed.
NOTE: It is not recommended selecting event conditions that do not agree on the same
lamp (for instance Tightening OK and Tightening NOK).
7. After configuring the event condition(s), on the lower-right corner of the Setup of lamp dialog
box, click Save.
If the behaviour of the Stacklight lamp is related to an AOP control, do the following to configure the
behaviour of each lamp of the Stacklight:
1. Starting from Lamp 1, select the Mounted check box: a lamp shows on the Stacklight image on
the left (see the figures below):
NOTE: Configure the lamps of the Stacklight starting from lamp 1 to lamp 5 (in
ascending order). Only the last configured lamp is editable.
For instance, after configuring all the lamps, to edit lamp 3, it is necessary to disable the
last configured lamps in this sequence: lamp 5 – lamp 4.
To disable a lamp, remove the check mark in correspondence of the Mounted check box.
2. In the drop-down list box under the Mounted check box, select a condition.