Programming Focus 61 Focus 61 User Guide
9839 0211 01 Edition 2.0 76 (118)
1. In the Buzzer section, select the Mounted check box.
2. Below the Mounted check box, click Setup.
3. In the Setup dialog box, select the Configured check box to associate the event condition to the
buzzer.
4. On the right of the Setup of buzzer dialog box, set the following parameters:
• Switch: from the Switch drop down list, select the status of the buzzer when the event
condition occurs. The available options are: On, Off.
• Flash: select the check box to enable the intermittence of the buzzer and type the time
during which the buzzer stay on/off. The time is in milliseconds.
• Next tight: select this option to change the buzzer status (on or off) at the next tightening.
• Time: type the time (in seconds) to elapse before the buzzer changes its status (on or off).
The Behaviour column summarizes the settings of the digital input.
5. Then, click Set.
NOTE: It is possible to set up to 10 event conditions.
After reaching the maximum number of configurable events, a warning message is
displayed.
NOTE: It is not recommended selecting event conditions that do not agree on the same
lamp (for instance Tightening OK and Tightening NOK).
6. After configuring the event condition(s), in the lower-right corner of the Setup of buzzer dialog
box, click Save.
To configure the buzzer functionality, if the behaviour of the Stacklight lamp is related to an AOP control:
1. In the Buzzer section, select the Mounted check box.
2. Below the Setup button, select the AOP control check box.