The Focus 61 display shows the tightening result of the last tightening:
Refer to the following results status list for possible results status that can be shown on the Focus 61
display:
Torque and angle within the limits (OK)
Torque and angle above the limits (Not OK)
Torque and angle below the limits (Not OK)
Torque below the limits, angle within the limits (Not OK)
Torque below the limits, angle above the limits (Not OK)
Torque within the limits, angle above the limits (Not OK)
Torque within the limits, angle below the limits (Not OK)
Torque above the limits, angle below the limits (Not OK)
Torque above the limits, angle within the limits (Not OK)
Existing fitting (double hit), torque within the limits
Existing fitting (double hit), torque above the limits
False direction of tightening (loosen)
Additional torque limit “overload screw” exceeded
Overload value of the wrench exceeded! Check calibration urgently!
Timeout expired, torque / angle are not OK
Timeout expired, torque / angle are OK
Maximum angular speed exceeded / it needs to be calibrated (Not OK)
Reading outside of the AD converter range (Not OK)
Additional information about the last tightening / Job in case of certain events
during the tightening operation (e.g. Overload)