Tightening
9836 3521 01 393
Mnemonic
Bit
no.
Description
TLM2
86
Final torque too low during monitoring on second buffer
AHM2
87
Angle too high during monitoring on second buffer
ALM2
88
Angle too low during monitoring on second buffer
BUFOVFLM2
89
Monitoring: Overflow in second recording buffer. See description of parameter
"Allow monitoring buffer overrun" in Program Settings.
MTR
90
Min Torque restriction exceeded
GHR
91
Gradient restriction, high limit exceeded
GLR
92
Gradient restriction, low limit exceeded
YAH
93
Yield angle, high limit exceeded
YAL
94
Yield angle, low limit exceeded
OTHER2
95
This is bit is set if any error bit(s) in the range 96 . 127 are set and only the first 12
bytes are included. That is, Type in the reporter is set to "I12".
SS
96
Slip Stick Error
SPINDLE
97
Spindle Error
CONFIG
98
Configuration error
DTH
99
Delta torque high alarm from check
DTL
100
Delta torque low alarm from check
CROT
101
Continue rotation
LTH
102
Low spot torque high alarm from check
LTL
103
Low spot torque low alarm from check
BAH
104
Backlash angle high alarm from check
BAL
105
Backlash angle low alarm from check
ZCH
106
Zero crossing high alarm from check
ZCL
107
Zero crossing low alarm from check
NOKINPUT
108
Step input not OK alarm from check

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco PowerMACS 4000 and is the answer not in the manual?

Atlas Copco PowerMACS 4000 Specifications

General IconGeneral
BrandAtlas Copco
ModelPowerMACS 4000
CategoryPower Tool
LanguageEnglish

Related product manuals