Peripheral Devices
602 9836 3521 01
The first found step defines the control strategy of the program.
Step type
Defines Control Strategy as
DT - Run until Dyna-TorkTM
DT2 - Run until Dyna-TorkTM, method 2
DT3 - Run until Dyna-TorkTM, method 3
T - Run until Torque
TC - Run until Torque with Current Control
Torque Control.
AO - Run until Angle with overshoot compensation
A - Run until Angle
PA - Run until Projected angle
TA – Run Torque-Angle with no stop
Angle Control.
All other step types
Undefined
Depending on the outcome of the Monitoring result and the Control strategy of the used program the result
for each bolt is indicated according to the following schemas:
Torque Control strategy:
TORQUE (Bolt T)
< ZDR
Low
OK
High
> Remove limit
ANGLE
(Bolt A)
Low
Yellow
Yellow
Yellow + Red
Yellow + Red
Red
OK
Yellow
Green
Yellow + Red
Red
High
Red
Red
Red
Red
If a REHIT is detected (see below for how) then the Yellow + Red outputs are set.
Angle Control strategy:
TORQUE (Bolt T)
< ZDR
Low
OK
High
> Remove limit
ANGLE
(Bolt A)
Low
Yellow
Yellow + Red
Yellow + Red
Yellow + Red
Red
OK
Yellow + Red
Green
Yellow + Red
Red
High
Red
Red
Red
Red
If a REHIT is detected (see below for how) then the Yellow + Red outputs are set.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Atlas Copco PowerMACS 4000 and is the answer not in the manual?

Atlas Copco PowerMACS 4000 Specifications

General IconGeneral
BrandAtlas Copco
ModelPowerMACS 4000
CategoryPower Tool
LanguageEnglish

Related product manuals