User's Manual 1008 Document #: LTRT-89730
Mediant 3000
Table 58-63: Tone Detection Parameters
Parameter Description
[DTMFDetectorEnable]
Enables the detection of DTMF signaling.
ï‚§ [0] = Disable
ï‚§
= Enable (default)
[MFR1DetectorEnable]
Enables the detection of MF-R1 signaling.
ï‚§ [0] = Disable (default)
ï‚§ [1] = Enable
[R1DetectionStandard] Determines the MF-R1 protocol used for detection.
ï‚§ [0] = ITU (default)
ï‚§ [1] = R1.5
Note: For the parameter to take effect, a device reset is required.
[UserDefinedToneDetectorEna
ble]
Enables the detection of User Defined Tones signaling, applicable
for Special Information Tone (SIT) detection.
ï‚§ [0] = Disable (default)
ï‚§
= Enable
[SITDetectorEnable]
Enables SIT detection according to the ITU-T recommendation
E.180/Q.35.
ï‚§ [0] = Disable (default)
ï‚§ [1] = Enable
To disconnect IP-to-ISDN calls when a SIT tone is detected, the
following parameters must be configured:
ï‚§ SITDetectorEnable = 1
ï‚§ UserDefinedToneDetectorEnable = 1
ï‚§ ISDNDisconnectOnBusyTone = 1 (applicable for Busy, Reorder
and SIT tones)
Another parameter for handling the SIT tone is SITQ850Cause,
which determines the Q.850 cause value specified in the SIP
Reason header that is included in a 4xx response when a SIT tone
is detected on an IP-to-Tel call.
To disconnect IP-to-CAS calls when a SIT tone is detected, the
following parameters must be configured:
ï‚§ SITDetectorEnable = 1
ï‚§ UserDefinedToneDetectorEnable = 1
ï‚§ DisconnectOnBusyTone = 1 (applicable for busy, reorder, and
SIT tones)
Notes:
ï‚§ For the parameter to take effect, a device reset is required.
ï‚§ The IP-to-ISDN call is disconnected on detection of a SIT tone
only in call alert state. If the call is in connected state, the SIT
does not disconnect the call. Detection of busy or reorder tones
disconnect these calls also in call connected state.
ï‚§ For IP-to-CAS calls, detection of busy, reorder, or SIT tones
disconnect the call in any call state.
[UDTDetectorFrequencyDeviati
on]
Defines the deviation (in Hz) allowed for the detection of each
signal frequency.
The valid range is 1 to 50. The default is 50.
Note: For the parameter to take effect, a device reset is required.