User's Manual 700 Document #: LTRT-89730
Mediant 3000
• In the Software Upgrade Key Status page, check that the listed features and
capabilities activated by the installed Software License Key match those that
were ordered.
• Access the Syslog server and ensure that the following message appears in the
Syslog server:
"S/N___ Key Was Updated. The Board Needs to be Reloaded with ini file\n"
5. Reset the device; the new capabilities and resources enabled by the Software License
Key are active.
Note:
If the Syslog server indicates that the Software License Key was
unsuccessfully loaded (i.e., the "SN_" line is blank), do the following preliminary
troubleshooting procedures:
1. Open the Software License Key file and check that the "S/N" line appears. If it
does not appear, contact AudioCodes.
2. Verify that you have loaded the correct file. Open the file and ensure that the first
line displays "[LicenseKeys]".
3. Verify that the content of the file has not been altered.
44.2.2.2 Installing Software License Key through AcBootP
The following procedure describes how to install a Software License Key using
AudioCodes AcBootP utility.
Notes:
• When loading the Software License Key file, a cmp file must also be loaded during
this BootP process.
• For more information on using the AcBootP utility, refer to the document AcBootP
Utility User's Guide.
 To install a Software License Key using the AcBootP utility:
1. Change the file extension name of the Software License Key file from .txt to .ini.
2. Place the Software License Key file in the same folder in which the device's cmp file is
located.
3. Start the AcBootP utility.
4. Click the Client Configuration tab, and then from the 'INI File' drop-down list, select
the Software License Key file.
5. From the 'BootP File' drop-down list, select the device's cmp file.
6. Configure the initial BootP/TFTP parameters as required, and then click Apply.
7. Reset the device; the cmp and Software License Key files are loaded to the device.

Table of Contents

Other manuals for AudioCodes Mediant 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 3000 and is the answer not in the manual?

AudioCodes Mediant 3000 Specifications

General IconGeneral
BrandAudioCodes
ModelMediant 3000
CategoryGateway
LanguageEnglish

Related product manuals