User's Manual 56. Testing SIP Signaling Calls
To configure SBC call testing:
1. Configure the test call parameters (for a full description, see ''SIP Test Call
Parameters'' on page 857):
a. Open the Test Call Settings page (Configuration tab > System menu > Test
Call > Test Call Settings).
Figure 56-7: Test Call Settings Page
b. In the 'Test Call ID' field, enter a prefix number for the simulated test endpoint on
the device.
c. In the 'SBC Test ID' field, enter a called prefix number for identifying the call as
an SBC test call.
d. Click Submit.
2. Configure regular SBC call processing rules for called number prefix "101", such as
classification and IP-to-IP routing through a proxy server.
56.7 Test Call Configuration Examples
Below are a few examples of test call configurations.
Single Test Call Scenario: This example describes the configuration of a simple test
call scenario that includes a single test call between a simulated test endpoint on the
device and a remote endpoint.
Figure 56-8: Single Test Call Example
Test Call table configuration:
Endpoint URI: "101"
Called URI: "201"
Route By: Dest Address
Destination Address: "10.30.40.01"
SIP Interface: SIPInterface_0
Call Party: Caller
Test Mode: Once
Alternatively, if you want to route the test call using the Tel-to-IP Routing table for the
Gateway application, configure the following:
Test Call table configuration:
Endpoint URI: 101@10.0.0.1
Route By: GW Tel2IP

Table of Contents

Other manuals for AudioCodes Mediant 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 3000 and is the answer not in the manual?

AudioCodes Mediant 3000 Specifications

General IconGeneral
BrandAudioCodes
ModelMediant 3000
CategoryGateway
LanguageEnglish

Related product manuals