46.2.10 Automatic Update Configuration Examples
This section provides a few examples on configuring the Automatic Update feature.
46.2.10.1 Automatic Update for Single Device
This simple example describes how to configure the Automatic Update feature for updating
a single device. In this example, the device queries the provisioning server for software,
configuration and Auxiliary files every 24 hours.
 To set up Automatic Provisioning for single device (example):
1. Set up an HTTP Web server (e.g., http://www.company.com) and place all the
required configuration files on this server.
2. Configure the device with the IP address of the DNS server for resolving the domain
name (e.g., http://www.company.com) that is used in the URL of the provisioning
server. You configure this in the Interface table:
• ini File:
[ InterfaceTable ]
FORMAT InterfaceTable_Index =
InterfaceTable_ApplicationTypes,
InterfaceTable_InterfaceMode, InterfaceTable_IPAddress,
InterfaceTable_PrefixLength, InterfaceTable_Gateway,
InterfaceTable_VlanID, InterfaceTable_InterfaceName,
InterfaceTable_PrimaryDNSServerIPAddress,
InterfaceTable_SecondaryDNSServerIPAddress,
InterfaceTable_UnderlyingDevice;
InterfaceTable 0 = 6, 10, 10.15.7.95, 16, 10.15.0.1, 1,
"Voice", 80.179.52.100, 0.0.0.0, "vlan 1";
[ \InterfaceTable ]
3. Configure the device with the following Automatic Update settings:
a. Automatic Update is done every 24 hours (1440 minutes):
♦ ini File:
AutoUpdateFrequency = 1440
b. Automatic Update of software file (.cmp):
♦ ini File:
AutoCmpFileUrl = 'https://www.company.com/sw.cmp'
c. Automatic Update of Call Progress Tone file:
♦ ini File:
CptFileURL =
'https://www.company.com/call_progress.dat'
d. Automatic Update of ini configuration file:
♦ ini File:
IniFileURL = 'https://www.company.com/config.ini'
e. Enable Cyclical Redundancy Check (CRC) on downloaded ini file:
♦ ini File:
AUPDCheckIfIniChanged = 1
4. Power down and then power up the device.