Version 7.0 397 Mediant 3000
User's Manual 20. Coders and Profiles
Parameter Description
AudioCodes sales representative.
Notes:
To configure the detection sensitivity level, use the 'AMD
Sensitivity Level' parameter.
For more information on the AMD feature, see Answering
Machine Detection (AMD) on page 221.
The corresponding global parameter is
AMDSensitivityParameterSuit.
AMD Sensitivity Level
[IpProfile_AMDSensitivityLevel]
Defines the AMD detection sensitivity level of the selected AMD
Parameter Suite (using the 'AMD Sensitivity Parameter Suite'
parameter).
For Parameter Suite 0, the valid range is 0 to 7, where 0 is for best
detection of an answering machine and 7 for best detection of a
live call. For any Parameter Suite other than 0, the valid range is 0
to 15, where 0 is for best detection of an answering machine and
15 for best detection of a live call.
Note: The corresponding global parameter is AMDSensitivityLevel.
AMD Max Greeting Time
[IpProfile_AMDMaxGreetingTim
e]
Defines the maximum duration (in 5-msec units) that the device
can take to detect a greeting message.
The valid range value is 0 to 51132767. The default is 300.
Note: The corresponding global parameter is
AMDMaxGreetingTime.
AMD Max Post Silence
Greeting Time
[IpProfile_AMDMaxPostSilence
GreetingTime]
Defines the maximum duration of silence from after the greeting
time is over (configured by AMDMaxGreetingTime) until the
device's AMD decision.
Note: The corresponding global parameter is
AMDMaxPostGreetingSilenceTime.
GW (Gateway Calls)
Profile Preference
[IpProfile_IpPreference]
Defines the priority of the IP Profile, where 20 is the highest priority
and 1 the lowest priority.
Notes:
If an IP Profile and a Tel Profile apply to the same call, the
coders and other common parameters of the profile with the
highest preference are applied to the call. If the preference of
the profiles is identical, the Tel Profile parameters are applied.
If the coder lists of both an IP Profile and a Tel Profile apply to
the same call, only the coders common to both are used. The
order of the coders is determined by the preference.
The parameter is applicable only to the Gateway application.
Coders
[IpProfile_CodersGroupID]
Assigns a Coders Group, which defines coders supported by the
SIP entity associated with the IP Profile.
The value, Default Coders Group represents the coders configured
in the Coders table (see Configuring Coders on page 381). All
other optional values (e.g., Coders Group 1), represent the coders
defined for the specific Coder Group configured in the Coder Group
Settings table (see Configuring Coder Groups on page 385).
Media Security Mode Defines the handling of SRTP for the SIP entity associated with the
IP Profile.