User's Manual 50 Document #: LTRT-89730
Mediant 3000
Figure 4-5: Serial Connection with PC for CLI Communication for TP-8410
2. Establish serial communication (e.g., telnet) with the device using a terminal emulator
program such as HyperTerminal, with the following communication port settings:
• Baud Rate: 115,200 bps
• Data Bits: 8
• Parity: None
• Stop Bits: 1
• Flow Control: None
3. At the prompt, type the login username (default is "Admin" - case sensitive):
login: Admin
4. At the prompt, type the password (default is "Admin" - case sensitive):
password: Admin
5. At the prompt, type the following command to access the Configuration folder:
/>CONF
6. View the current network settings, by typing the following command:
/CONFiguration>GCP IP
7. Change the network settings, by typing the following command:
/CONFiguration>SCP IP <IP address> <subnet mask> <Default Gateway>
You must enter all three network parameters, each separated by a space, for
example:
/CONFiguration>SCP IP 10.13.77.7 255.255.0.0 10.13.0.1
8. Save your changes and reset the device, by typing the following command:
/CONFiguration>SAR
9. For HA mode, repeat the above steps for the second blade.
10. Cable the device to your network. You can now access the device's management
interface using this new OAMP IP address.

Table of Contents

Other manuals for AudioCodes Mediant 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 3000 and is the answer not in the manual?

AudioCodes Mediant 3000 Specifications

General IconGeneral
BrandAudioCodes
ModelMediant 3000
CategoryGateway
LanguageEnglish

Related product manuals