Table 27-4: Charge Codes Table Parameter Descriptions
Parameter Description
Index
[ChargeCode_Index]
Defines an index number for the new table row.
Note: Each row must be configured with a unique index.
End Time (1 - 4)
[ChargeCode_EndTime<1-
4>]
Defines the end of the time period in a 24 hour format, hh. For
example, "04" denotes 4 A.M.
Notes:
ï‚§ The first time period always starts at midnight (00).
ï‚§
It is mandatory that the last time period of each rule end at midnight
(00). This prevents undefined time frames in a day.
Pulse Interval (1 - 4)
[ChargeCode_PulseInterval<
1-4>]
Defines the time interval between pulses (in tenths of a second). Once
the call is established, the device generates a pulse for each pulse
interval.
Pulses On Answer (1 - 4)
[ChargeCode_PulsesOnAns
wer<1-4>]
Defines the number of pulses that the device generates upon call
answer.