Field Name Description
AMD Information relating to the Automatic Machine Detection (AMD) feature:
V - voice
A - answer machine
S - silence
U - unknown
% Information relating to AMD that shows the success that the answering type
(probability) was correctly detected
SIPTrmReason
SIP call termination reason (BYE, CANCEL, or SIP error codes, e.g., 404)
SipTermDesc
Description of SIP termination reason:
SIP Reason header, if exists, for example: SIP ;cause=200 ;text="Call
completed elsewhere".
If no SIP Reason header exists, the description is taken from the reason
text, if exists, of the SIP response code, for example: "417 Unknown
Resource-Priority".
If no reason text exists in the SIP response code, the description is taken
from an internal SIP response mapping mechanism. For example, if the
device receives a SIP response "422", it sends in the CDR "422 Session
Interval Too Small method" as the description.
PstnTermReason
Q.850 protocol termination reason (0-127).
LatchedRtpIp
Remote IP address of the incoming RTP stream that the device "latched" on
to as a result of the RTP latching mechanism for NAT traversal.
LatchedRtpPort
Remote RTP port of the incoming RTP stream that the device "latched" on
to as a result of the RTP latching mechanism for NAT traversal.
LatchedT38Ip
Latching of a new T.38 stream - new IP address
LatchedT38Port
Latching of a new T.38 stream - new port
52.2.1.3.1 Release Reasons in CDR for Gateway Application
The possible reasons for call termination for the Gateway application which is represented
in the CDR field TrmReason are listed below:
"REASON N/A"
"RELEASE_BECAUSE_NORMAL_CALL_DROP"
"RELEASE_BECAUSE_DESTINATION_UNREACHABLE"
"RELEASE_BECAUSE_DESTINATION_BUSY"
"RELEASE_BECAUSE_NOANSWER"
"RELEASE_BECAUSE_UNKNOWN_REASON"
"RELEASE_BECAUSE_REMOTE_CANCEL_CALL"
"RELEASE_BECAUSE_UNMATCHED_CAPABILITIES"
"RELEASE_BECAUSE_UNMATCHED_CREDENTIALS"
"RELEASE_BECAUSE_UNABLE_TO_HANDLE_REMOTE_REQUEST"
"RELEASE_BECAUSE_NO_CONFERENCE_RESOURCES_LEFT"
"RELEASE_BECAUSE_CONFERENCE_FULL"
"RELEASE_BECAUSE_VOICE_PROMPT_PLAY_ENDED"
"RELEASE_BECAUSE_VOICE_PROMPT_NOT_FOUND"

Table of Contents

Other manuals for AudioCodes Mediant 3000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 3000 and is the answer not in the manual?

AudioCodes Mediant 3000 Specifications

General IconGeneral
BrandAudioCodes
ModelMediant 3000
CategoryGateway
LanguageEnglish

Related product manuals