Version 7.0 833 Mediant 3000
User's Manual 58. Configuration Parameters Reference
Parameter Description
[1] = Web interface is read-only.
When in read-only mode, parameters can't be modified. In addition, the
following pages can't be accessed: 'Web User Accounts', 'Certificates',
'Time and Date', 'Maintenance Actions' and all file-loading pages ('Load
Auxiliary Files', 'Software Upgrade Wizard', and 'Configuration File').
Notes:
For the parameter to take effect, a device reset is required.
To return to read/write after you have applied read-only using the
parameter (set to 1), you need to reboot your device with an ini file
that doesn't include the parameter, using the AcBootP utility.
[ResetWebPassword] Resets the username and password of the primary ("Admin") and
secondary ("User") accounts to their default settings ("Admin" and
"Admin" respectively), and deletes all other users that may have been
configured.
[0] = (Default) Password and username retain their values.
[1] = Password and username are reset.
Notes:
For the parameter to take effect, a device reset is required.
You cannot reset the username and password through the Web
interface (by loading an ini file or on the AdminPage). To reset the
username and password:
BootP: Set the parameter in an ini file and load it to the device
through BootP (for more information, refer to the AcBootP Utility
User's Guide).
SNMP:
1) Set acSysGenericINILine to WEBPasswordControlViaSNMP =
1, and reset the device with a flash burn (set
acSysActionSetResetControl to 1 and acSysActionSetReset to
1).
2) Change the username and password in the
acSysWEBAccessEntry table. Use the following format:
Username acSysWEBAccessUserName: old/pass/new
Password acSysWEBAccessUserCode: username/old/new
[WelcomeMessage] Enables and defines a Welcome message that appears on the Web
Login page for logging in to the Web interface.
The format of the ini file table parameter is:
[WelcomeMessage ]
FORMAT WelcomeMessage_Index = WelcomeMessage_Text
[\WelcomeMessage]
For Example:
FORMAT WelcomeMessage_Index = WelcomeMessage_Text
WelcomeMessage 1 = "**********************************" ;
WelcomeMessage 2 = "********* This is a Welcome message ***" ;
WelcomeMessage 3 = "**********************************" ;
Notes:
Each index row represents a line of text in the Welcome message
box. Up to 20 lines (or rows) of text can be defined.
The configured text message must be enclosed in double quotation
marks (i.e., "...").
If the parameter is not configured, no Welcome message is