User's Manual 966 Document #: LTRT-89730
Mediant 3000
Parameter Description
Line Code
[LineCode]
Selects B8ZS or AMI for T1 spans, and HDB3 or AMI for E1 spans.
[0] B8ZS = (Default) B8ZS line code (for T1 trunks only).
[1] AMI = AMI line code.
[2] HDB3 = HDB3 line code (for E1 trunks only).
[LineCode_x] Same as the description for parameter LineCode, but for a specific
trunk ID (where 0 denotes the first trunk).
[AdminState] Defines the administrative state for all trunks.
[0] = Lock the trunk; stops trunk traffic to configure the trunk
protocol type.
[1] = Shutting down (read only).
[2] = (Default) Unlock the trunk; enables trunk traffic.
Notes:
For the parameter to take effect, a device reset is required.
When the device is locked from the Web interface, the
parameter changes to 0.
To define the administrative state per trunk, use the
TrunkAdministrativeState parameter.
[TrunkAdministrativeState_x]
Defines the administrative state per trunk, where x denotes the
trunk number.
[0] = Lock the trunk; stops trunk traffic to configure the trunk
protocol type.
[1] = shutting down (read only).
= (Default) Unlock the trunk; enables trunk traffic.
Line Build Out Overwrite
[LineBuildOut.OVERWRITE]
Overwrites the Framer's XPM register values. These registers
control the line pulse shape.
[0] OFF = (Default) No overwrite.
[1] ON = Overwrite.
Line Build Out Loss
[LineBuildOut.Loss]
Defines the line build out loss for the selected T1 trunk.
[0] 0 dB (default)
[1] -7.5 dB
[2] -15 dB
[3] -22.5 dB
Note: The parameter is applicable only to T1 trunks.
Line Build Out XPM0
[LineBuildOut.XPM0]
Defines the Framer's XPM0 register value (line pulse shape
control).
The range is 0 to 255. The default is 0.
Note: The parameter is applicable only when the parameter
TrunkConfig.LineBuildOut.Overwrite is set to 1.
Line Build Out XPM1
[LineBuildOut.XPM1]
Defines the Framer's XPM1 register value (line pulse shape
control).
The range is 0 to 255. The default is 0.
Note: Applicable only when TrunkConfig.LineBuildOut.Overwrite is
set to 1.