Alarm acHASystemFaultAlarm
"Switch-Over:
Reason =
Network
Monitor error.
Failed table rows
index: <id 1>
up to <id 10>"
HA was lost due to
switchover due to the HA
Network Monitor feature as
the threshold of
unreachable rows (in the HA
Network Monitor table) was
exceeded. The indices of
these unreachable rows are
provided in the alarm's text.
The HA mode should return
automatically after a few
minutes. No corrective
action is required.
"Switch-Over:
Reason = Keep
Alive error"
HA was lost due to
switchover and should
return automatically after a
few minutes. Corrective
action is not required.
"Switch-Over:
Reason = DSP
error"
HA was lost due to
switchover and should
return automatically after a
few minutes. Corrective
action is not required.
Note: Applicable only to
Mediant 4000.
"Switch-Over:
Reason =
Software
upgrade"
HA was lost due to
switchover and should
return automatically after a
few minutes. Corrective
action is not required.
"Switch-Over:
Reason =
Software
upgrade - switch
back"
HA was lost due to
switchover (Hitless Software
Upgrade process switched
from the active to
redundant device) and
should soon return
automatically. Corrective
action is not required.
"Switch-Over: HA was lost due to
- 108 -

Table of Contents

Other manuals for AudioCodes Mediant 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 800 and is the answer not in the manual?

AudioCodes Mediant 800 Specifications

General IconGeneral
ProtocolsSIP, H.323
Digital Interfaces1/2 E1/T1 PRI
ManagementWeb, CLI, SNMP
Mounting19-inch rack
CodecsG.711, G.729, G.722, G.723.1
Power Supply100-240V AC
Operating Temperature0 to 40°C
Storage Temperature-25 to 70°C
Humidity10% to 90% non-condensing