CHAPTER7 SNMP Traps
Mediant 800 SBC | SNMP Reference Guide
Alarm acHASystemFaultAlarm
Reason = Fk
upgrade"
switchover caused by a
Hitless License Upgrade
process and should return
automatically after a few
minutes. Corrective action is
not required.
“Switch-Over:
Reason =
Manual switch
over"
HA was lost due to
switchover and should
return automatically after a
few minutes. Corrective
action is not required.
"Switch-Over:
Reason = Higher
HA priority"
HA was lost due to
switchover to unit with
higher HA priority and
should return automatically
after a few minutes.
Corrective action is not
required.
Major HA feature is
active, but the
system is not
operating in HA
mode.
"SYS_HA: Invalid
Network
configuration, fix
it and reboot
Redundant unit -
no HA system!"
HA synchronization process
has failed. Correct invalid
network configuration and
then restart the Redundant
device in order to trigger HA
synchronization again.
“SYS_HA: Offline
configuration
was changed, HA
is not available
until next
system reboot.
HA synchronization process
has failed. Changing
configuration that requires
a device reset to apply the
new configuration must be
done before the standalone
system can become HA
again.
“SYS_HA:
Redundant is
not
reconnecting
after deliberate
restart, No HA
system.”
HA synchronization process
has failed. Manually reboot
the Redundant device.
- 109 -

Table of Contents

Other manuals for AudioCodes Mediant 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 800 and is the answer not in the manual?

AudioCodes Mediant 800 Specifications

General IconGeneral
ProtocolsSIP, H.323
Digital Interfaces1/2 E1/T1 PRI
ManagementWeb, CLI, SNMP
Mounting19-inch rack
CodecsG.711, G.729, G.722, G.723.1
Power Supply100-240V AC
Operating Temperature0 to 40°C
Storage Temperature-25 to 70°C
Humidity10% to 90% non-condensing