EasyManua.ls Logo

AudioCodes Mediant 800 - Page 118

AudioCodes Mediant 800
195 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CHAPTER7 SNMP Traps
Mediant 800 SBC | SNMP Reference Guide
Alarm acHASystemFaultAlarm
Reason = Fk
upgrade"
switchover caused by a
Hitless License Upgrade
process and should return
automatically after a few
minutes. Corrective action is
not required.
“Switch-Over:
Reason =
Manual switch
over"
HA was lost due to
switchover and should
return automatically after a
few minutes. Corrective
action is not required.
"Switch-Over:
Reason = Higher
HA priority"
HA was lost due to
switchover to unit with
higher HA priority and
should return automatically
after a few minutes.
Corrective action is not
required.
Major HA feature is
active, but the
system is not
operating in HA
mode.
"SYS_HA: Invalid
Network
configuration, fix
it and reboot
Redundant unit -
no HA system!"
HA synchronization process
has failed. Correct invalid
network configuration and
then restart the Redundant
device in order to trigger HA
synchronization again.
“SYS_HA: Offline
configuration
was changed, HA
is not available
until next
system reboot.
HA synchronization process
has failed. Changing
configuration that requires
a device reset to apply the
new configuration must be
done before the standalone
system can become HA
again.
“SYS_HA:
Redundant is
not
reconnecting
after deliberate
restart, No HA
system.”
HA synchronization process
has failed. Manually reboot
the Redundant device.
- 109 -

Table of Contents

Other manuals for AudioCodes Mediant 800

Related product manuals