EasyManuals Logo

AudioCodes Mediant 800 Reference Guide

AudioCodes Mediant 800
195 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #119 background imageLoading...
Page #119 background image
CHAPTER7 SNMP Traps
Mediant 800 SBC | SNMP Reference Guide
Alarm acHASystemFaultAlarm
Minor HA Network
Monitor feature
will not be the
cause of a
switchover as the
'Preempt Mode'
parameter is
configured to
Enable and the
'Preempt Priority'
is configured to a
level.
"Network
Monitor switch-
over is blocked
when HA
Preemptive
mode and
Priority is
configured"
-
The HA Network
Monitor feature
will not be the
cause of a
switchover as the
number of
Ethernet Groups
(Ethernet links) in
the redundant
device in "up"
status are less
than on the active
device.
"Network
Monitor switch-
over is blocked
when status of
Ethernet links on
redundant is
worse than on
active unit"
-
The Ethernet
Group that is
associated with
the Maintenance
IP interface, used
for HA systems, is
configured with
two ports and
one of them goes
down (i.e., no 1+1
Ethernet port
redundancy)
"SYS_HA:
Maintenance
redundant link is
down - no HA
maintenance
link
redundancy"
Make sure that the
network cable is firmly
plugged into the
Ethernet port.
Make sure that the
other end of the
network cable is
correctly connected to
the network.
Cleared HA system is
active.
- -
- 110 -

Table of Contents

Other manuals for AudioCodes Mediant 800

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AudioCodes Mediant 800 and is the answer not in the manual?

AudioCodes Mediant 800 Specifications

General IconGeneral
ProtocolsSIP, H.323
Digital Interfaces1/2 E1/T1 PRI
ManagementWeb, CLI, SNMP
Mounting19-inch rack
CodecsG.711, G.729, G.722, G.723.1
Power Supply100-240V AC
Operating Temperature0 to 40°C
Storage Temperature-25 to 70°C
Humidity10% to 90% non-condensing

Related product manuals