12/16
Operating Instructions ACU
157
15.5.1 Block diagram
The following table describes the software switches shown in the circuit diagram as a function of the
selected Reference Percentage Source 476.
Operation
Mode
MFI1A
FP
MP
F3
EM-S1INA
Sign
1
1
Abs. value
2
1
Abs. value
4
1
1
Abs. value
10
1
Abs. value
11
1
1
Abs. value
12
1
1
Abs. value
14
1
1
1
Abs. value
20
1
Abs. value
21
1
1
Abs. value
22
1
1
Abs. value
24
1
1
1
Abs. value
32
1
Abs. value
33
1
1
Abs. value
90
1
1
1
1
Abs. value
95
CANopen Object 0x6071
Abs. value
96
Profibus OUT-PZD3
Abs. value
99
Output FT output percentage 1
Abs. value
101...199
Operation modes 1...99 with sign (+/-)
+/-