EasyManuals Logo

BONFIGLIOLI active cube 201 User Manual

BONFIGLIOLI active cube 201
285 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #67 background imageLoading...
Page #67 background image
12/16
Operating Instructions ACU
67
7.5.3 Size 5 ACU 401 (18.5 to 30.0 kW)
DANGER
Disconnect the frequency inverter from mains voltage and protect it against being
energized unintentionally.
Verify safe isolation from power supply.
Work on the device may only be started once the DC link capacitors have discharged.
The time to wait is at least 3 minutes in the case of size 5.
When the frequency inverter is disconnected from power supply, the mains, DC-link
voltage and motor terminals may still be live for some time.
Switch off power supply before connecting or disconnecting the mains cable to/from
terminal X1, the motor cables and the brake resistor to/from terminal X2.
0.5 … 35 mm
AWG 20 … 2
2
18.5 kW … 30.0 kW
PHOENIX MKDSP 25/ 6-15,00-F
0.5 … 25 mm
AWG 20 … 4
2
1.00 … 25 mm
AWG 18 … 4
2
1.5 … 25 mm
AWG 16 … 4
2
+
-
L1
L2 L3L1
L2 L3 PE
3ph / 400V AC
X1
X1
2.5 Nm
22.1 lb-in

Table of Contents

Other manuals for BONFIGLIOLI active cube 201

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the BONFIGLIOLI active cube 201 and is the answer not in the manual?

BONFIGLIOLI active cube 201 Specifications

General IconGeneral
BrandBONFIGLIOLI
Modelactive cube 201
CategoryDC Drives
LanguageEnglish

Related product manuals