Control Panels Keypad Installer menu | en 103
Bosch Security Systems, Inc. Installation Manual 2018.07 | 16 | F.01U.287.180
Poll Rate (seconds)
Format
AES Size
AES Entry
1. Enter the installer passcode, and then open the [1] Installer Menu.
2. Go to [1] Programming Menu > [1] Reporting > [2] Network > [2] Enhanced Comm
Parms. The keypad shows the first destination and its address.
3. Use /Previous or /Next to the destination you want to edit.
4. Depending on keypad model:
Press Edit.
-or-
Press Enter and Enter again.
5. Delete existing characters, if necessary, and then enter the new address.
6. Press Save or Enter. The keypad shows Parameter saved.
7. Depending on keypad model:
Press Port # and Edit.
-or-
Press Next and Enter and then Enter.
8. Delete existing characters, if necessary, and then enter the new number.
9. Press Save or Enter. The keypad shows Parameter saved.
10. Depending on keypad model:
Press Poll Rate and Enter.
-or-
Press Next and Enter and then Enter.
11. Delete existing characters, if necessary, and then enter the new poll rate.
12. Press Save or Enter. The keypad shows Parameter saved.
13. Depending on keypad model:
Press Format and Edit.
-or-
Press Next and Enter and then Enter.
14. Press the icon or softkey for the desired option or use /Previous or /Next to select
the desired format, Modem4 or Contact ID.
15. Press Save or Enter. The keypad shows Parameter saved.
16. Depending on keypad model:
Press AES Size and Edit.
-or-
Press Next and Enter and then Enter.
17. Press the softkey for the desired option or use /Previous or /Next to select the
desired size.
18. Press Save or Enter. The keypad shows Parameter saved.
19. Escape from the menu.
20.1.3 [1] Reporting > [3] Routing menu parameters
Use routing to program primary and backup destinations over standard telephone lines, local
area network (LAN) or wide area network (WAN). In this menu, you can designate the primary
and backup destinations for up to four routes.