Control Panels Keypad Installer menu | en 107
Bosch Security Systems, Inc. Installation Manual 2018.07 | 16 | F.01U.287.180
4. Delete the existing number, if necessary, and then enter the new number. Use /
Previous or /Next to move to a different byte.
5. Press Save or Enter. The keypad shows Parameter saved.
6. Escape from the menu.
Default Gateway
1. Enter the installer passcode, and then open the [1] Installer Menu.
2. Go to [1] Programming Menu > [2] Network > [1] Ethernet > (choose the bus module or
on-board) > [2] Address Parameters > [3] Default Gateway.
3. Press Edit or Enter to edit the gateway.
4. Delete the existing number, if necessary, and then enter the new number. Use /
Previous or /Next to move to a different byte.
5. Press Save or Enter. The keypad shows Parameter saved.
6. Escape from the menu.
HTTP Port Number
1. Enter the installer passcode, and then open the [1] Installer Menu.
2. Go to [1] Programming Menu > [2] Network > [1] Ethernet > (choose the bus module or
on-board) > [2] Address Parameters > [4] Port Number.
3. Press Edit or Enter to edit the port number.
4. Delete the existing number, if necessary, and then enter the new number.
5. Press Save or Enter. The keypad shows Parameter saved.
6. Escape from the menu.
20.1.7 [2] Network > [1] Ethernet > (choose the bus module or on-board) > [3]
DNS Parameters menu
IPv4 Server Address
1. Enter the installer passcode, and then open the [1] Installer Menu.
2. Go to [1] Programming Menu > [2] Network > [1] Ethernet > (choose the bus module or
on-board) > [3] DNS Parameters > [1] IPv4 Server Addr. The keypad shows the IPv4
Server Address current configuration.
3. Press Edit or Enter to edit the IPv4 Server Address.
4. Delete the existing number, if necessary, and then enter the new number. Use /
Previous or /Next to move to a different byte.
5. Press Save or Enter. The keypad shows Parameter saved.
6. Escape from the menu.
IPv6 Server Address
1. Enter the installer passcode, and then open the [1] Installer Menu.
2. Go to [1] Programming Menu > [2] Network > [1] Ethernet > (choose the bus module or
on-board) > [3] DNS Parameters > [2] IPv6 Server Addr. The keypad shows the IPv6
Server Address current configuration.
3. Press Edit or Enter to edit the IPv6 Server Address.
4. Delete the existing number, if necessary, and then enter the new number. Use /
Previous or /Next to move to a different byte.
5. Press Save or Enter. The keypad shows Parameter saved.
6. Escape from the menu.

Table of Contents

Other manuals for Bosch B4512

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch B4512 and is the answer not in the manual?

Bosch B4512 Specifications

General IconGeneral
Control Panel TypeHybrid
Wired Zones8
Outputs2
Programmable Outputs2
Onboard EthernetYes
Cellular CommunicationOptional
SeriesB Series
Partitions2
TypeControl Panel
ModelB4512
ManufacturerBosch
Input Voltage16.5 VAC
Communication FormatsContact ID, SIA
Power Supply16.5 VAC
Backup Battery12 V, 7 Ah
Operating Temperature0°C to +50°C
Weight1.5 kg
CompatibilityBosch accessories