108 en | Keypad Installer menu Control Panels
2018.07 | 16 | F.01U.287.180 Installation Manual Bosch Security Systems, Inc.
Module Hostname
1. Enter the installer passcode, and then open the [1] Installer Menu.
2. Go to [1] Programming Menu > [2] Network > [1] Ethernet > (choose the bus module or
on-board) > [3] DNS Parameters > [3] Module Hostname. The keypad shows the current
hostname.
3. Press Edit or Enter to edit the hostname.
4. Delete the existing number, if necessary, and then enter the new number. Use /
Previous or /Next to move to a different byte.
5. Press Save or Enter. The keypad shows Parameter saved.
6. Escape from the menu.
20.1.8 [2] Network > [2] Cellular > (choose the SDI2 cellular module or plug-in
module)
You can use a B44x cellular communication module for communication. Plug it directly into the
control panel or use it with a B450 module.
Module 1 settings Module 2 settings
Access Point Name _______________________________ _______________________________
Access Pt Username _______________________________ _______________________________
Access Pt Passcode _______________________________ _______________________________
SIM PIN _______________________________ _______________________________
Access Point Name
1. Enter the installer passcode, and then open the [1] Installer Menu.
2. Go to [1] Programming Menu > [2] Network > [2] Cellular > (choose the SDI2 cellular
module or plug-in module) > [1] Access Point Name. The keypad shows the current
configuration.
3. Press Edit or Enter to edit the configuration.
4. Delete existing characters, if necessary, and then enter the new characters.
5. Press Save or Enter. The keypad shows Parameter saved.
Access Pt Username
1. Enter the installer passcode, and then open the [1] Installer Menu.
2. Go to [1] Programming Menu > [2] Network > [2] Cellular > (choose the SDI2 cellular
module or plug-in module) > [2] Access Pt Username. The keypad shows the current
configuration.
3. Press Edit or Enter to edit the configuration.
4. Delete existing characters, if necessary, and then enter the new characters.
5. Press Save or Enter. The keypad shows Parameter saved.
Access Pt Passcode
1. Enter the installer passcode, and then open the [1] Installer Menu.
2. Go to [1] Programming Menu > [2] Network > [2] Cellular > (choose the SDI2 cellular
module or plug-in module) > [3] Access Pt Password. The keypad shows the current
configuration.
3. Press Edit or Enter to edit the configuration.

Table of Contents

Other manuals for Bosch B4512

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch B4512 and is the answer not in the manual?

Bosch B4512 Specifications

General IconGeneral
Control Panel TypeHybrid
Wired Zones8
Outputs2
Programmable Outputs2
Onboard EthernetYes
Cellular CommunicationOptional
SeriesB Series
Partitions2
TypeControl Panel
ModelB4512
ManufacturerBosch
Input Voltage16.5 VAC
Communication FormatsContact ID, SIA
Power Supply16.5 VAC
Backup Battery12 V, 7 Ah
Operating Temperature0°C to +50°C
Weight1.5 kg
CompatibilityBosch accessories