104 en | Keypad Installer menu Control Panels
2018.07 | 16 | F.01U.287.180 Installation Manual Bosch Security Systems, Inc.
Options include:
No Device, Phone 1, Phone 2, Phone 3, Phone 4, SDI2-1 D1, SDI2-1 D2, SDI2-1 D3, SDI2-1 D4,
SDI2-2 D1, SDI2-2 D2, SDI2-2 D3, SDI2-2 D4, Onboard D1, Onboard D2, Onboard D3, Onboard
D4, Cellular D1, Cellular D2, Cellular D3, Cellular D4.
Route 1 Route 2 Route 3 Route 4
Primary Device No Device ___________ ___________ ___________ ___________
Backup Device No Device ___________ ___________ ___________ ___________
Primary (Destination)
1. Enter the installer passcode, and then open the [1] Installer Menu.
2. Go to [1] Programming Menu > [1] Reporting > [3] Routing.
3. Use /Previous or /Next to scroll through the list of routes and go to the route you
want to program.
4. Press Edit or Enter to edit the route.
5. Use /Previous or /Next to scroll through the list of devices (for destination 1) and
go to the destination 1 option you want to select for the current device (for example,
Phone 1). To keep destination 1, escape from the menu. To change to a different
destination (2, 3, or 4), press [Edit Destination], and continue to the next step.
6. Press Save or Enter. The keypad shows Parameter saved.
7. Escape from the menu.
Backup (Destination)
Notice!
Keypads show and allow you to select the Backup Destination Device only after you select a
Primary Destination Device.
1. Enter the installer passcode, and then open the [1] Installer Menu.
2. Go to [1] Programming Menu > [1] Reporting > [3] Routing.
3. Use /Previous or /Next to scroll through the list of routes and go to the route you
want to program.
4. Press Edit or Enter to edit the route.
5. Use /Previous or /Next to scroll through the list of devices (for destination 1) and
go to the destination 1 option you want to select for the current device (for example,
Phone 1). To keep destination 1, escape from the menu. To change to a different
destination (2, 3, or 4), press [Edit Destination], and continue to the next step.
6. Press Save or Enter. The keypad shows Parameter saved.
7. Escape from the menu.
20.1.4 [1] Reporting > [4] Personal Note menu parameters
The control panel can send text messages and emails for personal notification over Ethernet
or using a cellular communicator. You can configure up to 16 destinations using a combination
of cellular phone numbers and email addresses. The system considers an email address valid
if you copy it exactly as it appears from an internet email provider. In this menu, you can add a
phone number or email address to each personal notification identifier (1 through 16).
Notification
Number
Phone number or email address

Table of Contents

Other manuals for Bosch B4512

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch B4512 and is the answer not in the manual?

Bosch B4512 Specifications

General IconGeneral
Control Panel TypeHybrid
Wired Zones8
Outputs2
Programmable Outputs2
Onboard EthernetYes
Cellular CommunicationOptional
SeriesB Series
Partitions2
TypeControl Panel
ModelB4512
ManufacturerBosch
Input Voltage16.5 VAC
Communication FormatsContact ID, SIA
Power Supply16.5 VAC
Backup Battery12 V, 7 Ah
Operating Temperature0°C to +50°C
Weight1.5 kg
CompatibilityBosch accessories