110 en | Keypad Installer menu Control Panels
2018.07 | 16 | F.01U.287.180 Installation Manual Bosch Security Systems, Inc.
Use Previous or Next to toggle between the option to edit the address as an IPv4
address or as a hostname. Press Enter when the keypad shows the option you want to
edit.
4. Delete the existing characters, if necessary, and enter the new characters. For an IPv4
address, use /Previous or /Next to move to a different byte, and use the number
keys to enter the new numbers. For a hostname, press a number key repeatedly to scroll
through the number and letters shown on the key.
5. Press Save or Enter. The keypad shows Parameter saved.
6. Escape from the menu.
20.1.12 [3] RPS > [4] RPS Port Number menu parameters
In this menu, you can specify the destination port for outgoing RPS or Installer Services Portal
programming tool (available in Europe, Middle East, Africa, and China) session requests to the
specified IP address.
RPS Port Number
1. Enter the installer passcode, and then open the [1] Installer Menu.
2. Go to [1] Programming Menu > [3] RPS > [4] RPS Port Number.
3. Press Edit or Enter to edit the RPS port number.
4. Delete the existing number, if necessary, and then enter the new number.
5. Press Save or Enter. The keypad shows Parameter saved.
6. Escape from the menu.
20.1.13 [4] Area Options menu parameters
This parameter enables or disables specified areas. Enabled areas must have assigned account
numbers. In this menu, you can turn on or off areas and assign area account numbers.
Notice!
Account numbers can contain characters 0 through 9, and B through F.
Area 1 Area 2 Area 3 Area 4
Area On Yes/No Yes/No Yes/No Yes/No
Account Number ______________ ______________ ______________ ______________
Area State
1. Enter the installer passcode, and then open the [1] Installer Menu.
2. Go to [1] Programming Menu > [4] Areas.
3. Use /Previous or /Next to go to the desired area.
4. Depending on keypad model:
Press Edit and then Yes or No.
-or-
Press Enter to edit the area and Enter to edit the Area On state for the selected area. Use
Previous or Next to toggle between the Yes and No options.
5. Press Save or Enter. The keypad shows Parameter saved.
6. Escape from the menu.

Table of Contents

Other manuals for Bosch B4512

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch B4512 and is the answer not in the manual?

Bosch B4512 Specifications

General IconGeneral
Control Panel TypeHybrid
Wired Zones8
Outputs2
Programmable Outputs2
Onboard EthernetYes
Cellular CommunicationOptional
SeriesB Series
Partitions2
TypeControl Panel
ModelB4512
ManufacturerBosch
Input Voltage16.5 VAC
Communication FormatsContact ID, SIA
Power Supply16.5 VAC
Backup Battery12 V, 7 Ah
Operating Temperature0°C to +50°C
Weight1.5 kg
CompatibilityBosch accessories

Related product manuals