Modbus Address
Notation
Register Name
Access
367
Ext84
The high word of measured data is on External 84
R/W
368
Ext84
The low word of measured data is on External 84
R/W
369
Ext85
The high word of measured data is on External 85
R/W
370
Ext85
The low word of measured data is on External 85
R/W
371
Ext86
The high word of measured data is on External 86
R/W
372
Ext86
The low word of measured data is on External 86
R/W
373
Ext87
The high word of measured data is on External 87
R/W
374
Ext87
The low word of measured data is on External 87
R/W
375
Ext88
The high word of measured data is on External 88
R/W
376
Ext88
The low word of measured data is on External 88
R/W
377
Ext89
The high word of measured data is on External 89
R/W
378
Ext89
The low word of measured data is on External 89
R/W
379
Ext90
The high word of measured data is on External 90
R/W
380
Ext90
The low word of measured data is on External 90
R/W
381
Ext91
The high word of measured data is on External 91
R/W
382
Ext91
The low word of measured data is on External 91
R/W
383
Ext92
The high word of measured data is on External 92
R/W
384
Ext92
The low word of measured data is on External 92
R/W
385
Ext93
The high word of measured data is on External 93
R/W
386
Ext93
The low word of measured data is on External 93
R/W
387
Ext94
The high word of measured data is on External 94
R/W
388
Ext94
The low word of measured data is on External 94
R/W
389
Ext95
The high word of measured data is on External 95
R/W
390
Ext95
The low word of measured data is on External 95
R/W
391
Ext96
The high word of measured data is on External 96
R/W
392
Ext96
The low word of measured data is on External 96
R/W
Note: If the register value is 4294967294, then there is a communication error.
8.1.2.3 External Channels 4 Bytes Data (Float Type)
Modbus Address
Notation
Register Name
Access
1001
Ext1
Measured data on External 1
R/W
1003
Ext2
Measured data on External 2
R/W
1005
Ext3
Measured data on External 3
R/W
1007
Ext4
Measured data on External 4
R/W
1009
Ext5
Measured data on External 5
R/W
1011
Ext6
Measured data on External 6
R/W
1013
Ext7
Measured data on External 7
R/W
1015
Ext8
Measured data on External 8
R/W
1017
Ext9
Measured data on External 9
R/W
1019
Ext10
Measured data on External 10
R/W
1021
Ext11
Measured data on External 11
R/W
1023
Ext12
Measured data on External 12
R/W
1025
Ext13
Measured data on External 13
R/W
1027
Ext14
Measured data on External 14
R/W
1029
Ext15
Measured data on External 15
R/W
1031
Ext16
Measured data on External 16
R/W
1033
Ext17
Measured data on External 17
R/W
1035
Ext18
Measured data on External 18
R/W
1037
Ext19
Measured data on External 19
R/W
1039
Ext20
Measured data on External 20
R/W
1041
Ext21
Measured data on External 21
R/W
1043
Ext22
Measured data on External 22
R/W
1045
Ext23
Measured data on External 23
R/W

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Brainchild PR10 and is the answer not in the manual?

Brainchild PR10 Specifications

General IconGeneral
BrandBrainchild
ModelPR10
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals