BRP-Rotax
INSTALLATION MANUAL
Fusebox Regula-
tor A
The regulator plate A needs to be connected with the EMS Ground (cable lugs on the (en-
gine-) wiring harness). The terminal is conducted as a M4 screw connection suitable for
cable lug according to DIN 46225 (Tightening torque: 1.2 Nm (11 in. lb)). The cable lugs
need to be evenly spread onto the three available terminals.
Figure 3.8: Fusebox -Regulator A
1
Regulator
2
Regulator plate A
3 Ground terminals
NOTICE
A connection between regulator plate A and airframe ground should only be
done during supply of the EMS System by an external power source (e.g. during
engine start).
Effectivity: 916 i A / C24
Edition 0/Rev. 1
24–00–00
Page 9