EasyManua.ls Logo

Carrier Access Access Navigator - Connect DSX-1 Cables to Access Navigator

Carrier Access Access Navigator
704 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Access Navigator - Release 1.8 August 2003 6-11
Electrical Installation
Connect DSX-1 Cables to Access Navigator
Connect DSX-1 Cables to Access Navigator
CAUTION! SHIELDED DSX-1 CABLES WITH FERRITE BEAD RF SUPPRESSORS ARE
REQUIRED FOR COMPLIANCE WITH NEBS 1089 EMI/EMC AND FCC REQUIREMENT
P
ART 15, TO PREVENT RADIO FREQUENCY INTERFERENCE WITH OTHER EQUIPMENT.
E
NSURE THAT SHIELD DRAIN GROUND LUG IS GROUNDED TO CHASSIS THROUGH DS1
CONNECTOR.
NOTE: Use only #4-40 × 3/8" locking screws provided in Accessory Kit.
1. Refer to Figure 6-5.
2. Remove locking screw, if any, from DS1 Receive (IN) connector (see Figure 6-5).
3. Plug receive DSX-1 cable into DS1 Receive (IN) connector and snap clamp over cable side of
connector.
4. Position spade lug of shield drain wire under connector locking screw (#4-40 × 3/8") and tighten
with screw driver.
5. Verify that spade lug is firmly secured.
Figure 6-5. Location of Rear Panel DS1 Connectors
Insert shield drain
ground lug under
connector screw.
DS1 Transmit (OUT)
Connector
DS1 Receive (IN)
Connector
Connect the DSX-1 transmit and
receive cable plug ends with the
shield lug wires to the Access
Navigator. Note that both DSX-1
cables are identical (PN 005-0025).
Clamp
Clamp
Ground lug
DS1
Receive
IN
DS1
Transmit
OUT
Ti mi ng
In
Alarm Out
-48V
B
-48V
A
Alarm
In
Link OK
Ethernet
RS-232
CLI

Table of Contents