EasyManua.ls Logo

Carrier Access Access Navigator - Set Remote RS232 Data; Set Remote RS232 Stop

Carrier Access Access Navigator
704 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Access Navigator - Release 1.8 August 2003 18-121
CLI Language Reference
CLI Command List
Syntax: set remote <n> rs232 baud <setting>
Example: set remote 9 rs232 baud 57600
Set Remote RS232 Data
Purpose: Sets Access Bank II remote RS-232 interface data bits and parity.
Security: Level 2 (operator)
Syntax: set remote <n> rs232 data <e7|o7|n8>
Example: set remote 9 rs232 data n8
Set Remote RS232 Stop
Purpose: Sets Access Bank II remote RS-232 interface stop bits.
Security: Level 2 (operator)
Syntax: set remote <n> rs232 stop <1|2>
Example: set remote 9 rs232 stop 1
Field Description
n DS1 number, 1 to 32
setting Baud rate selections are:
1200, 2400, 4800, 9600, 19200, 38400, 57600
Field Description
n DS1 number, 1 to 32
e7 7 bit data, even parity
o7 7 bit data, odd parity
n8 8 bit data, no parity
Field Description
n DS1 number, 1 to 32.
1|2 Number of stop bits, 1 or 2.