6-54 August 2003 Access Navigator - Release 1.8
Electrical Installation
Verify Operation
6. Verify that status indicators now show Controller B is active.
Requirement: CONTROLLER A POWER indicator lights green.
Requirement: CONTROLLER B POWER indicator lights green.
Requirement: CONTROLLER A ACTIVE/STANDBY indicator is off.
Requirement: CONTROLLER B ACTIVE/STANDBY indicator lights green.
7. Verify that Controller B is now in active mode by entering following command:
status equipment
Requirement: Equipment status display shows Controller B is in Active mode.
NOTE: If status indications are not correct, refer to Diagnostics & Troubleshooting on
page 15-1.
8. When you are finished with the management session, you must log out and exit from the Access
Navigator by entering the following command:
exit
Replace Front Cover
DANGER! FIRE HAZARD. STANDARDS UL 1950 AND C22.2 NO. 950.95 REQUIRE
THAT ALL ACCESS COVERS BE REPLACED TO PREVENT FIRES FROM SPREADING TO
NEARBY EQUIPMENT.
Replace front cover and tighten screws.