Access Navigator - Release 1.8 August 2003 A-5
EOC Interface
Analog Line Termination Objects
Analog Line Termination Objects
This object class is used to manage analog lines at the points where they originate or terminate. The
Access Navigator inherently creates one instance of this object class for each GR-303 DS0 on a “drop”
type DS1. The Create command can also be used to create an Analog Line Termination over the EOC.
Alarm Count List Objects
This object class contains a summary of the alarms that have not been cleared at the RDT. The Access
Navigator inherently creates one instance of this object class if the switch type is DMS. The Create
command may also be used to create an instance over the EOC.
The Create command will establish the GR-303 alarm count list at the physical location of the DS0
containing the Call Reference Value (CRV). CRVs can only be moved using CLI commands.
Table A-1 Analog Line Termination Objects
Attribute Support Command Support
Create Get Set Delete
objectClass Yes Yes
analogLineTermId Yes Yes Yes
primaryServiceState Yes Yes
secondaryServiceState Yes Yes
genSigFuncCode Yes Yes Yes
lineCircuitAddress Yes Yes
alarmSeverityAssignmentList Yes Yes Yes
Optional Attributes
callRefValue Yes Yes
redlined Yes Yes
currentProblemList Yes Yes
Table A-2 Alarm Count List Objects