11-26 August 2003 Access Navigator - Release 1.8
Provision Remote Access Bank II
Configure Remote V.35 Interface (if used)
Configure Remote V.35 Interface (if used)
1. Show current remote interface settings with the following command:
show remote <n|all>
Example: show remote 11
Example: show remote all
The show command will display the remote interface settings the each DS1 specified, or for all
DS1s. For example, the message for showing DS1 number 11 would look similar to the following:
Settings for remote device Remote Device #11:
Remote Config: enabled
T1 Drop Port:
Line Coding: AMI
Framing: D4
Line Build Out: DSX-1 0-133 ft. (or 0 db)
PRM: AT&T
V.35 Port:
CTS: Always High
Rx Timing: Internal
Clock Inversion: None
Data Inversion: Normal
Speed: Nx64
DSU: On
RS232 Port:
Baud Rate: 9,600
Data Bits: 8
Parity: None
Stop Bits: 1
2. If drop V.35 settings are correct, skip remaining steps.