Access Navigator - Release 1.8 August 2003 6-47
Electrical Installation
Verify Alarm Input Connections
Verify Alarm Input Connections
NOTE: Alarm inputs produce Minor Alarm events tagged with input number. For
example, Alarm Input 1 produces the CLI message “Alarm Input 1 Detected”.
Verify input alarm functions as follows:
Momentarily short-circuit pins for each alarm input pair (l, 2, 3 in Figure 6-31) to simulate an
alarm contact closure. See Alarm Input Connections on page 6-31.
Requirement: Contact closure on any alarm input wire pair produces Minor Alarm indica-
tion on active Controller card (see Figure 6-32).
Figure 6-31. Location of Rear Panel Alarm Input Connector
Figure 6-32. Location of Active Controller and Minor Alarm Indicators
NOTE: If status indications are not correct, refer to Diagnostics & Troubleshooting on
page 15-1.