EasyManua.ls Logo

Carrier Access Access Navigator - Make BITS Cable (Optional); Connect BITS Cable

Carrier Access Access Navigator
704 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6-26 August 2003 Access Navigator - Release 1.8
Electrical Installation
Make BITS Cable (Optional)
Make BITS Cable (Optional)
To make an RJ48C timing input cable, perform the following steps (see Figure 6-13).
Follow standard practices for wiring cables.
Use RJ48 connectors.
Use cable rated for Category 3 (CAT3) or better.
Use straight cable wiring, with identical pin connections on both plug ends.
Use twisted pair wires for receive pair.
Use continuity tester to verify pin connections.
Figure 6-13. RJ48C Cable Construction
Connect BITS Cable
Connect RJ48C timing input cable to Timing In connector on rear panel of Access Navigator (see Figure
6-14). Push plug in until it clicks in place.
Figure 6-14. Location of Timing Input (BITS) Connector
Timing Input Jack
(Front View)
1
RJ48C Plug
(Pin Side)
Pins
Pin 1
RingTip
Receive
Twisted Pair
2
RJ48 Plug
Timing In (BITS)

Table of Contents