Carrier Access Access Navigator - Test DS1 and DS0 Circuits; Turn up Service

Carrier Access Access Navigator
704 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Access Navigator - Release 1.8 August 2003 9-19
Provision DCS Service
Turn Up Service
Turn Up Service
1. Show current DS1 status with the following command:
status ds1 <n>
Example: status ds1 1-32
2. Show current DS0 status with the following command:
status ds0 <n:ch>
Example: status ds0 1:1-24
Example: status ds0 8:1-24
3. If drop DS1 and DS0 settings are correct, skip remaining steps.
4. Set DS1s and DS0s to in-service (up) status with the following commands:
set ds1 <n> up
set ds0 <n:ch> up
Example: set ds1 5 up
Example: set ds0 5:1-6
Test DS1 and DS0 Circuits
NOTE: The Access Navigator supports the following T1.403 loop tests:
• Responds to ESF bit patterned loop requests (when loopdetect is on)
• Generates ESF bit patterned loop requests
• Generates SF CSU inband loopcodes
1. Follow standard practices to test subscriber drop DS1 circuits.
2. Follow standard practices to test DS0 connections.

Table of Contents