Access Navigator - Release 1.8 August 2003 16-19
Maintenance Procedures
Replace Quad T1 Framer Card
Replace Quad T1 Framer Card
Procedure Summary
n Overview ... 16-3
n Precautions ... 16-4
n Tools and Materials Required ... 16-4
n Verify Equipment Status ... 16-5
n Determine Which Replacement Procedure to Use ... 16-5
n Replace Protected Controller Card ... 16-6
n Replace Unprotected Controller Card ... 16-13
Overview
This procedure provides steps for replacing a Quad T1 Framer (QF) card. The Access Navigator
can hold up to eight QF cards, providing a total of 32 DS1 circuits. QF cards are hot-swappable and
can be installed at any time, without interrupting service on other cards, except when the card is
providing a DS1 clock source used for system timing.
Each Quad T1 Framer card contains four DS1 circuits. DS1 circuit numbers are determined by the
QF card slot (see also Figure 16-10):
QF Card Slot DS1 Circuit Numbers
#11234
#25678
#3 9 101112
#4 13 14 15 16
#5 17 18 19 20
#6 21 22 23 24
#7 25 26 27 28
#8 29 30 31 32

Table of Contents