Access Navigator - Release 1.8 August 2003 15-11
Diagnostics & Troubleshooting
Status and Performance
Status and Performance
n Status Clock ... 15-11
n Status DS0 ... 15-12
n Status DS1 ... 15-13
n Status DS1 All ... 15-14
n Status DS1 Performance ... 15-16
n Status DS1 Performance History ... 15-17
n Clear DS1 Performance ... 15-18
n Status Equipment ... 15-19
n Status IP ... 15-20
n Status Remote ... 15-21
Status Clock
Displays the currently active clock source, along with the primary and secondary clock settings and
clock source status.
Syntax: status clock
Message:
Active Clock Source: DS1 12
Primary:
Clock Source: DS1 12
Clock Status: In Service
Secondary:
Clock Source: INTERNAL
Clock Status: In Service
Description:
Item Description
Active Clock The clock source currently being used.
Clock Source DS1 number – DS1 clock recovered by receiver.
BITS – external
Building Integrated
Timing Supply.
INTERNAL – internal
Stratum clock oscillator.
Clock Status In Service (working), Out of Service.